Skip to content

OX-TRAN ® 2/48

The OX-TRAN 2/48 series is the ideal solution for ambient whole package testing for OTR, testing more packages in less time than traditional methods.

The OX-TRAN® 2/48 series of Oxygen Transmission Rate (OTR) analyzers are designed for ambient testing of complete packages or other 3-dimensional samples. These 8 cell instruments provide high throughput to increase the testing capacity of your laboratory. The 2-bank design allows 4 samples to be conditioned at the same time as the 4 samples are being examined. This parallel operation greatly increases the efficiency of the analyzer while still providing the accurate and repeatable results you expect from MOCON. They utilize the same interchangeable package testing cartridge designs as our other package testing analyzers and fixtures. These revolutionary cartridges offer simplified sample preparation and improved repeatability of test results. There is a wide variety of cartridge designs available to accommodate different package sizes and types, many without the use of epoxy.

Add to Enquiry

Description

High Efficiency Package Testing

  • Parallel conditioning and testing cells increase throughput
  • Automated conditioning cycle reduces time to prepare samples for testing
  • High Flow purge cycle is up to 20 times faster than traditional methods
  • Simple and secure One-button pneumatic cartridge mounting
  • Easy to use package test cartridges save time to prepare samples
  • Quick response Coulox sensor reduces testing time

Trusted Results

  • MOCON Patented Coulox® sensor is absolute and never needs calibration
  • Long Life Coulometric sensor with exclusive 4 -year warranty
  • Intrinsic sensor fully complies with ASTM D 3985
  • Integrate TruSeal to minimize background levels for more accurate results
  • Automated Flow and RH control on carrier gas for both conditioning and test cells

The OX-TRAN 2/48 analysers can test the Oxygen Transmission Rate (OTR) on both films and packages from low to high barriers.

The simple user interface with automated controls makes testing easy with little training.  In certain applications, starting a new test may be a simple as a press of a button after the sample is mounted.  Common tests methods can be stored and recalled for reuse.  For new or unknown sample types, the Auto-Test function will automatically adjust the test parameters to provide optimized test results without having experience with the package.

A variety of testing cartridges are available to test trays, bottles, flexible containers, pouches, cups, pods, caps, closures, cartons, films and just about any other type of 3-dimensional sample. Custom designed cartridges are also available to simplify sample preparation and improve testing repeatability.

Models

This family of instruments has 2 models with different lower detection limits.

  • H Model (common barriers) – detection range from 0.00025 to 1 cc/package*day
  • L Model (high barriers) – is able to achieve a factor of 10 lower than the H Model providing a range from 0.000025 to 1 cc/package * day

Standards

  • ASTM D3985
  • JIS 126-B
  • ASTM FF1927
  • DIN 53380-3
  • ASTM F 2622
  • ASTM F1307 packages
  • ISO 15105-2

For more than 25 years, MOCON’s OX-TRAN series of instruments have been the most trusted and longest lasting on the market. The OX-TRAN 2/48 series is the newest option available that takes whole package testing to the next level allowing brand owners and packaging service providers the ability to reliably test their finished packages. It is the perfect complement to any testing laboratory who frequently tests complete packages or other 3-dimensional samples.

Features & Benefits

Variety of Package and Film Test Cartridges

  • Easy sample prep on the benchtop, many without epoxy
  • One button quick release and loading
  • Single use mounting foil plates simplifies package mounting
  • Specialized cartridge options save time and improve test repeatability

Advanced Package Testing Features

  • Smart conditioning with automatic quick purge to desired settings
  • Automatic high flow conditioning mode shortens cycle
  • Quick check verifies package is mounted properly before start of test
  • Parallel conditioning and examinations increase testing efficiency

Automated Control Features

  • Flow & RH control on carrier gas (both conditioning and test cells)
  • “Auto-test” method Development and Recommendations for unknown samples
  • Test report printing and export
  • Sensor Protection

Touchscreen Interface

  • Intuitive automated operation requires less training
  • Clear graphic display of test and instrument status
  • Built in multi-level user management and data security
  • Event log & trouble shooting guide

COULOX® Sensor

  • Short exam times reduces overall test time to increase throughput
  • No sensor calibration required
  • Long sensor life with 4-year warranty
  • Intrinsic sensor fully complies with ASTM D3985

TruSeal®

  • Eliminate Individual Zero
  • More repeatable results
  • Allows tool-less mounting of cartridges

Warranty

  • Full 100% parts and workmanship warranty for 12 months
  • Exclusive 4-year warranty on the Coulox sensor

Technical Specifications

Capabilities – Model Specific

Units Model L Model H
Test Ranges
@20.9% O2
cc/(m2 x day) 0.005 to 200 0.05 to 200
cc/(pkg x day) 0.000025 to 1.0 0.00025 to 1.0
Test Ranges Compensated to 100% O2 cc/(m2 x day) 0.025 to 1000 0.25 to 1000
cc/(pkg x day) 0.000125 to 5.0 0.00125 to 5.0
Resolution cc/(pkg x day) 0.00001 0.0001
Repeatability cc/(pkg x day) 0.00001 or ± 2%* 0.0001 or ± 2%*

*of reading/degree C in ambient whichever is greater

Capabilities – All Models

OX-TRAN 2/48 Series Units
Test Temperature Range Ambient
Controlled RH Testing Range Ambient
Controlled RH Carrier Range (both conditioning and examination cells) 0, 30% to 90% ± 5%

Other Specifications:

Physical Specifications

  • 16.25” H x 32.25” W x 22.25” D (41.3 cm x 82.1 cm x 56.6 cm)
  • 110 Lbs. (50 kg)

Electrical Requirements

  • Voltage: 100 – 240 VAC 50/60 Hz
  • Maximum Power Draw: 700 VA

Laboratory Requirements

Temperature Operation 21 °C ± 2 °C
Storage 10 °C to 30 °C
Humidity Operation 10% to 60% RH (non-condensing)
Storage 5% to 85% RH (non-condensing)

Gas Supply Requirements

Carrier Gas Gas Composition Nitrogen/Hydrogen Mix (98%/2%)
Supply Pressure, Nominal 25 PSI, (1.72 Bar), (172 kPa)

Connectivity

  • Remote Access and Control (requires optional Perm-Net Light Software)
  • Standard Ethernet port (100T)
  • Dual USB 2.0 ports (for connection of keyboard, mouse or memory devices)

Compliance Standards

This product is UL and CSA listed using the ETL mark from Intertek Group plc. and is certified to conform to CE.

Conforms to the following internationally recognized safety standards.

  • IEC 61010-1:2010 Third Edition
  • UL 61010-1:2012 Third Edition
  • CAN/CSA-C22.2 No. 61010-1:2012 Third Edition

Conforms to the following internationally recognized EMC standards.

  • EN 61326-1:2013
  • EN 61000-3-2:2006, A1:2009, A2:2009
  • EN 61000-3-3:2013

Conforms to EU Directive 2011/65/EU RoHS Compliance.

Accessories

Cartridges & Options

  • 80 cm2 package testing cartridge
  • Large vertical tray testing cartridge
  • Flexible pouch testing cartridge
  • 50 cm2 film testing cartridge
  • Package adaptor cartridge
  • Coffee capsule cartridges, 10 cup or 1 cup
  • Capture volume cartridges
  • Custom engineered cartridges

Consumables

  • Cert Films
  • Single use package mounting foil plates

Software

  • 21 CFR Part 11 user and data security
  • Remote viewing software from a PC – PermNet Lite
  • PermWare data collection, data management and instrument status dashboard

Service & Support Options

  • Basic Preventative Maintenance Plan
  • Plus Preventative Maintenance Plan

Applications

Packaging Films

  • Monolayer
  • Multi-layer
  • Coated Films
  • Coated Paper/paperboard

Packages

  • Common food packages
  • Medical packages
  • Bottles/Closures

Test Standard Compliance

  • ASTM D3985
  • ASTM F2622
  • ASTM F1307
  • ASTM F1927
  • ISO CD 15105-2
  • JIS K-7126-B
  • DIN 53380-3
  • GB/T 19789-2005
  • GB/T 31354-2014

Test Methodology

Following ASTM D3985

Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor

The test specimen is mounted as a semi-barrier between two chambers at ambient atmospheric pressure. One chamber is slowly purged by a stream of nitrogen and the other chamber contains Oxygen. As Oxygen permeates through the film into the nitrogen carrier gas, it is transported to the coulometric detector where it produces an electrical current, the magnitude of which is proportional to the amount of oxygen flowing into the detector per unit of time.

Resources

 

RDM MEDeSEAL
RDM MEDeSEAL

UK Head Office

RDM Test Equipment Ltd
39 Golds Nurseries Business Park,
Jenkins Drive, Elsenham,
Hertfordshire,
CM22 6JX
United Kingdom

T: +44 (0)1279 817171
F: +44 (0)1279 815743
E: sales@rdmtest.com

USA Head Office

RDM Test Equipment LLC.
441 Old Hwy 8 NW Suite 203
New Brighton
Minneapolis
MN55112
USA

T: +1 651 766 2565
E: sales@rdmtest.com

RDM MEDeSEAL
ASTM standards logo
ISO 9001
Back To Top