Cooled Incubators

Product Ref: CI-Range

A range of Cooled Incubators, with capacities from 56 to 750 litres, and temperature range from -10deg.C to 70deg.C

Cooled Incubators feature intuitive easy to use controls with on screen guidance within a bold illuminated LCD display, offering precise time and temperature control from ambient 0°C to 70°C, cooling temperature range 0°C to 47°C (-10deg.C optional).

The Incubator can run at a set temperature immediately, delay start or commence to start in the future at a given date and time. Additionally with three available programs with up to 6 segments in each program which allows the creation of temperature time profiles of your choice.

All control surfaces feature smooth easy to wipe clean surfaces.

The digital microprocessor controls feature real time clock, diagnostics, digital LCD display to 0.1°C resolution, dual pt100 probes, including event log and data log of actual temperatures along with USB and RS232 interface. Every unit is supplied with a Calibration Certificate for validation.

Featuring a stainless steel interior with stainless steel outer case powder painted. Particular attention paid providing a good tight door closure and hinge design to maintain a sealed chamber in use. Case is well insulated to reduce heat loss in use. Access port fitted as standard.

 

Models:


NE7-56S 56 Litre Cooled Incubator, Fan Assist Circulation

NE7-112S 112 Litre Cooled Incubator, Fan Assist Circulation

NE7-240S 240 Litre Cooled Incubator, Fan Assist Circulation

NE7-400S 400 Litre Cooled Incubator, Fan Assist Circulation

NE7-750S 750 Litre Cooled Incubator, Fan Assist Circulation


Controls:


Featuring bold illuminated LCD graphic display of measured temperatures in real-time, in increments of ±0.1°C, with fan speed status, set temperature, date and time.

Intuitive to use controls, utilising illuminated touch sensitive keypads with display prompts assisting the setting of functions within the unit.

Option to set temperature in °C or °F.

The Incubator can be set to run at a set temperature immediately, delay start [dd:hh:mm] or commence to start in the future at a given time and date [hh:mm, yyyy:mm:dd].

With three available programs and up to 6 segments in each it allows the creation of temperature time profiles of your choice, including for example fan speed, exhaust air flap setting, fast achieve set temperature and a setting allowing programs to be cycled. Any of these programs they can run immediately, delay start [dd:hh:mm ] or commence to start in the future at a given time and date [hh:mm, yyyy:mm:dd]. And when a program is running the controls are locked preventing accidental interruption or change however stopping a program is straightforward.

 

Fan Speed:

The Fan speed can be set from 10% to 100% for maximum air convection in the chamber.


Exhaust air flap:

The Exhaust air flap can be set from 0% closed to 100% open and allows air from the chamber to vent in either heating or cooling modes.


Logger:

Data logging of minimum, average and maximum temperature values to USB.


Heat-up/Cooling Times:

0deg.C = 25mins

5deg.C = 20mins

40deg.C = 25 mins


Safety Features:

Switching on, the controls undergo an automatic diagnostic check.

Features a temperature sensor fail alarm with error reporting on LCD screen.

Power failure control with auto resume and event recording.

Setting of High and Low temperature Alarm, settable 0-5°C about set temperature.

Door opening generates an audible beep and indication on LCD display. When a program is running and should the door be left open a Door Alarm occurs, illuminating a red warning indicator and audible beeping until closed. Door open Alarm settable 0-5 minutes.

Over temperature protection can be selected in controls: Class 1 for overall unit protection or Class 2 for experiment/sample protection. Once protection is activated heating is switched off and a warning appears on screen. Class 3 protection, an accessory factory fit option, provides active protection once the temperature in chamber returns to normal values heating and control resumes.

 

Safety Class:

Fitted with Class 1 for overall unit protection and Class 2 for experiment/sample protection. Accessory factory fit option Class 3 provides self-resetting protection at set temperature.


Optional Accessories:

Temperature range increase - increases range to -10deg.C

Viewing window - 260mm x 260mm

Wire Shelf - Autoclaveable

Perforated stainless steel shelf

Photoperiodic System, 2 Lighting elements, ceiling mounted, day and night sim software

Photoperiodic System, 5 Lighting elements, door mounted, day and night sim software

Internal power socket for Fan Assisted S range - This factory fit accessory provides a UK 3pin 230V power supply inside the chamber of S series Clifton Incubator for powering Mixers or lighting.

Over temperature safety protection 3.1 - Accessory factory fit option Class 3 provides self-resetting protection at set temperature.

Interior lighting - Factory fit accessory - Incubator temperature range limited to a maximum 70°C

Walkabout insulative scoop tray - Working temperature range -196°C to 93°C, Durable and lightweight, Lid not required, Condensation Free, Can be cleaned simply hand wash with mild detergent and towel dry.

 

Notes:

  • Before ordering please check the room or building access where this unit will be installed and electrical power requirements.
  • Sensitivity measurements based on temperature readings on shelf in centre of the chamber.
  • Working capacity of chamber may be smaller.
  • Incubators up to 112 litres are stackable.
  • Do not place in direct sunlight or near a heat or cold source.
  • Allow a 100mm air gap away from wall at rear. Ensure there is a minimum 300mm air gap from top of the unit to ceiling.